I suppose it could be the shortage of intake air making the compressor work too hard, or lack of air circulation not allowing natural compressor cooling to take place. Check oil level. What does this mean?? Many Thanks. Anyone else know what Code 5 for a Kaeser is and how to correct the compressor fault? We'd welcome it here! Runs well but after filling cylinder won’t restart. My goal is to share knowledge about industrial air compressors and compressed air systems. When it comes to Kaeser service and repair for NH and MA businesses, United Compressor is only a phone call away. User manuals, KAESER Air Compressor Operating guides and Service manuals. Compressor Leaks Air If you shut down the compressor when the tank is filled with air and then find that the pressure gauge is showing a drop in pressure, you know that the compressor is leaking air. ". : ESD 250, ESD 300Standard Voltage: 460 V / 3 Phase / 60 HzEnvelope Dimensions Inches: 110"w x 79"d x 84"hSound Pressure Level Range: 76-77 db(A)Weight Range (lbs. Oil temperature gradually increase when in loading mode, until it reach the top limit (110 deg.Celcius), then shutting down. Pressure switch not making contact. The complete workings of the whole air compressor is explained. it is configurated star delta, Kaeser BSD50 RUNNING HOT AND SHUTTING DOWN , FAULT CODE W G ADT DID BLOW OUT OIL COOLER WITH AIR OIL OK ROOM TEMP OK. We have 2 SM11 units and had the same issue, went through everything, including replacing the thermostat. ___________________ S Series. 28 Pages. Since the user has total control over the conditions of the compressor lubricant, he assumes total responsibility for its safe usage. Kaeser Compressors provides products, services and complete systems for supplying production and work processes with quality compressed air. MY AIR COMPRESSOR SHOWS CODE 5 AND SHUTS DOWN RIGHT AFTER START UP. It actually drops in temp when running and increases in temp while idling. Has anybody seen temp.display erratic readings?enough to shut machine down? If compressor oil works its way into the air lines, the effects could be detrimental … The hoses are about $250 for the pair. These all have factory-trained sales and service people. Find local authorized air compressor distributors for sales and service. 2 Pages. We have a large inventory in our Kansas City warehouse ready to ship anywhere in the United States. What is the bottom line with P abd 5 mean? Kaeser M58 Utility Mount Air Compressor, 48 HP, 210 CFM at 100 psi, Kubota V2403CRE4B motor, price range: $22,500 to $23,000; Oil-free and oil-less models can add to your costs significantly. and all recorded data has been erased by unknown causes. See pressure switch adjustment. Compressor even runs warm when not loaded. If it’s a new installation, check the phase sequence. Dear sir, It keeps shutting down Air Discharge High Temp. Search by product number and find exactly the Kaeser compressor parts you need with confidence. Oil, filters, has just replaced a month ago. Want to save on energy and running costs? Compressed Air Filters. Your local distributor should be your first stop for almost any inquiry, including: Kaeser SM11 air compressor _____ Photo of controller DM1? Manufacturer: Kaeser; Up for sale is a used 2012 Kaeser rotary screw air compressor, model CSD100. More than 16 years on line helping folks with their air compressor problems! Kaeser ESD Rotary Screw Compressor (250hp-300hp) (816cfm-1500cfm) Product Features:Drive Motor Enclosure Type: TEFC (IP 55)Series ESD Model No. 2 Pages. 460 volt, 3 phase. To make compressed air understandable for everyone! Specialised KAESER-ser‐ workshop vice Defective non-return function of Repair or have replaced if nec‐ – the inlet valve. It shows it is on load but will not build pressure. 12 Pages. is bad? The solenoid valve leaks when the compressor is idle Non-return valve seal is defective Let the air in the tank flow out until all the pressure is released. Compressor shuts down on high-temperature It has worked flawlessly till this afternoon when it stopped building air. I CLEANED ALL FILTERS. This is a 146 page information-packed troubleshooting guide for oil-injected rotary screw air compressors. Coleman equipment stocks and sells Genuine OEM Kubota Engine Parts for your Kaeser Compressor. We have lists of common service parts to help you find what you need, or give one of our parts specialists a … I would check your hoses specifically the hose that runs from the compressor to the thermostatic block. You can expect to pay almost triple what you would for a traditionally lubricated compressor of the same size. _______________________ 3. With service centers nationwide and our 24-hour emergency parts guarantee, Kaeser customers can rely on the best after-sales support in the industry. Now it is giving a back pressure fault. The controller regulates the compressor package between load and idle. Pressure in the tank is below the cut-in pressure. We have a Kaiser CSD 100. If it is actually running hot and shutting down, could be the air end bearings… or maybe a gazillion other things, Fletch. It is more likely that it is compressor related, and I would be looking into the air end as a possible heat source. Cooler completely clean and doesn’t seem to be throwing off much heat. My Kaeser ASD37 is well regularly maintained. If the compressor package runs in idle for longer than the preset period (1) to (2), for example t1 = 6 minutes in idle, the drive motor is stopped completely (2). You don’t provide any details of your air compressor (model / HP) so I cannot even check for technical documents about your problem. The system solutions comprise compressed air generation and treatment and are designed for optimal overall efficiency. Hi, I’m a Kaesar engineer but never heard or seen this fault code before? Furthermore, the built-in web server enables you to display operational data, maintenance and fault messages on any PC. Kaeser Full Service ensures maximum reliability, availability, efficiency and value retention throughout a compressed air system's entire service life. It has worked flawlessly till this afternoon when it stopped building air. You’ve checked the power supply to the compressor pressure switch, across the pressure switch to the motor circuit, then to the capacitors, one of which will be the start cap and the other the run cap but the compressor won’t kick on. Turn on power. It has a flash point above 460F. I I have a Pic of the Sigma basic screen. Either an electrical problem, or the compressor has tripped on a safety device. Temperature switch tripped. The Kaeser Service and Repair Experts at United Compressor Have Earned a Flawless Track Record Over the Past 30 Years Companies in Dozens of Industries Depend on Us for Dependable, Timely Service for Their Kaeser Compressors. Unsure what you are looking for or can't find the part you need online? Loose incoming or power connection wires. SmartPipe+TM. Motor overloads not tripped or nor reset. Check power supply for adequate voltage. All-inclusive package for a flat-rate price. _______________________________________________eval(ez_write_tag([[300,250],'about_air_compressors_com-medrectangle-3','ezslot_0',139,'0','0'])); There are a number of reasons why an air compressor will overheat. Oil in Air Lines. Attention! All Kaeser Compressors catalogs and technical brochures. Make sure all power wires are tight at connections. Or, as you say, it could be the sensor if the compressor itself isn’t actually running hot. Today it has problem of overheating airend. Brian, I don’t have the compressor or the manual. asd 25 .new probe twice.new thermostats twice(with defective elements)mach does not overheat but shuts down on alarm adat mess. Tech support has us check the thermostat, that was fine. European Standards must be observed during installation, operation, maintenance and repair of the compressor package. While KAESER synthetic compressor oil is less flammable than equal viscosity mineral oils, it cannot be classified as a fire---resistant fluid. Get help with the most common problems for rotary screw compressors. Check supply power. (W. Henrietta, N.Y.)eval(ez_write_tag([[468,60],'about_air_compressors_com-banner-1','ezslot_4',147,'0','0'])); Oil, oil filter, separator and filters are all new. Please advise and what should to do? I have a Kaeser twin screw compressor we use in our countertop shop. The Air Systems Specialist With over 90 years of experience, Kaeser is the air systems specialist. Low oil level. – December 2020, The compressor appears to compress the air but there no air at the hose on a 921.166460 – December 2020, Bambi 75/250 won’t build air after being on its side – November 2020, About Different Brands of Air Compressors, Want to bragg about your gorgeous computer rebuild? Browse for Kaeser replacement parts and oils today. Free Compressed Air Basics CourseLearn about compressed air - click here, Learn about industrial compressed air systems and receive fresh articles in your inbox. Kaeser goes to market through a nationwide network of exclusive branches and distributors. 494 cfm at 125 psi. 61 Fault: oil flows from the compressor air filter after shutdown Service manual Portable compressor M122 No. I have a Kaeser twin screw compressor we use in our countertop shop. It is more likely that it is compressor related, and I would be looking into the air end as a possible heat source. Also we had a lot of buildup in the large hose on the top back of the unit that connects to the top of the cooler. Download 43 KAESER Air Compressor PDF manuals. When the lower switching point pmin(3) is reached, the compressor package is automatically started again. For local air compressor sales and service requirements, look no further than the Kaeser Compressors Melbourne Sales & Service Centre, located at the company's Australian head office in Dandenong. 4. I do need this up an running as it is used for the CNC and other processes in the shop. I believe this has happened once before and years ago so I don’t remember what was done to fix the problem. Replace your oil if necessary. 8 Pages. Kaeser SXC8 compressor had oil change plus all filters. 2. 45 Zenith Road Dandenong VIC 3175 03 9791 5999. 2012 Kaeser CSD100 100 hp rotary screw air compressor. Why is that? Faulty temperature switch. Our extensive 120,000 square foot facility allows us to provide unequaled product availability. It has 8,992 load hours, 35,778 total hours. Rotary Screw Compressors BSD Series – Brochure Flow rate 1.12 to 8.19 m³/min, Pressure 5.5 – 15 bar P-651/1ED PDF, 3.66 MB KAESER Report P-2000ED PDF, … If your Kaeser air compressor needs repair or maintenance you need an expert technician to get things done, and as one of the largest air compressor service provider in the region, we can definitely help your compressor in the condition where it needs to be to be fully operational. by: Carl. Room temperature is in the low 70’s. IT IS TELLING ME THERE IS SOMETHING WRONG WITH THE DRYER. Tab. Getting an fault code of DM 1 on a Kaeser SM11. Kaeser Air Compressor Reviews Try running the compressor with the compressor room door open to see if it makes any difference. Hi. It shows it is on load but will not build pressure. Automatic Magnetic Drain. Maybe temperature sensor Low voltage to unit. I would expect that the manual would identify the remedial action for any maintenance code. The Porter Cable compressor tank is full, but I can’t get air to come out? essary. Check for errors on display. Check/Change the back pressure valve/Vent Valve located at tank top. Kaeser Compressors, Inc. offers a complete line of air system products including rotary screw compressors with the highly efficient Sigma Profile and the Sigma Control system, Mobilair portable compressors, Omega rotary lobe and Sigma rotary screw blowers, vacuum packages, refrigerated and desiccant dryers, filters, condensate management systems and a variety of related products. Asd 25 .replaced temp.probe twice over 5 yrs.watching the temp on display as machine warms from cold start,smooth increase in steady graduations till approx.190° ,then fluctuates +/- up to 10° then mach shuts down.wait a minute restart.50 % chance it stays on then drops back to normal operating temp…. 1. And alarm will not clear. Our compressor parts and lubricants are 100% OEM compatible and manufactured to meet the specifications of Kaeser compressor models, including Kaeser’s AS series (30/50, 31/36/44), BS series (44, 50/60, 51/61), and CS series (75/90, 76, 90/120). Kaeser Air Compressor Parts If your compressor is making sounds it didn’t make before, there is a very big chance there is a part that needs to be replaced, and it’s advisable to make sure a technician will perform a thorough inspection to make sure there are no other issues that have developed because of this faulty worn out part (s). Air Treatment Solutions. ours was down to a pin hole and not allowing enough oil to go to the cooler fast enough. During the live Q&A portion of the webinar “Keep cool and go with the flow: How to fix temperature, pressure, and air quality issues with your compressed air system” (now available on demand) Kaeser Compressors product manager Werner Rauer and compressed air consultant Ron Marshall tackled several attendee questions related to combating common compressed air problems. Check emergency stop is out. Thanks. I believe this has happened once before and years ago so I don’t remember what was done to fix the problem. Air Compressor Trouble Shooting Guide. Then remove the non- return valve plug and clean the valve seal. High pressure switch tripped. Troubleshooting support: The industrial PC saves the last 200 operational events, helping you and Kaeser Support to quickly find and reproduce faults. ... Copco Belliss and Morcom Broomwade Compair Demag Elmo Rietschle Gardner Denver Hanshin Hitachi Holman Hydrovane Ingersoll Rand Kaeser Reavell Sullair Wilkerson. with KAESER and without KAESER ’s prior written consent will invali-date the warranty. You press the start button but nothing happens. Activated Carbon Tower. DSD, ESD, and FSD Series (125-450 hp) 20 Pages. Other visitors will comment on this I hope, but I expect that you probably will need assistance from Kaeser to help you, wherever you are in the world. 100 hp. Try running the compressor with the compressor room door open to see if it makes any difference. Any help would be great. I have a Kaeser air compressor overheating shutting off , is there a specific volume of air that needs to inlet and exhaust. Common rotary screw compressor problems and issues that have been reported. I have a CSD 75 T kaeser and my question is if in FLA the compressor runs 96A and the drivemotor runs 84A why the main contactor overload is set to 56A acording to manual. We support all major air compressor brands for your repair and maintenance needs, additionally, we offer new industrial air compressor … Check fuses. 8 Pages. Red led comes on and must be reset to run again. My guide will show you how to troubleshoot the most common air compressor problems. Could you repost the question with a photo of the controller showing the fault please? Kaeser Compressor Service and Repair - 24 Hours We are the premier Kaeser Air Compressor Service and Repair Experts in the Philadelphia Region, including New Jersey and Delaware. Push the reset button. No electrical power. If necessary, replace the seal and then reinstall all components. Kaeser Kompressoren was founded in 1919 and Kaeser USA's headquarters opened in 1982. If you wish to be updated when new comments are posted, add: www.about-air-compressors.com/feed/ to your RSS reader. If yet again, Pay Kaeser, They will take care. Attention! With compressors, operation failure could stem from one of the other issues covered in this air compressor troubleshooting guide. SX - HSD Series. by Fletch You don’t provide any details of your air compressor (model / HP) so I cannot even check for technical documents about your problem. Or select your model number to find corresponding replacement parts. Check and reset the overload relay.